Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 14(9)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38732361

RESUMO

This comprehensive review explores the intricate aspects of left ventricular thrombus (LVT), a potential complication in both ischemic and non-ischemic cardiomyopathies. It provides a thorough understanding of left ventricular thrombus, revealing its uncommon incidence in the general population (7 cases per 10,000 patients), predominantly linked to ischemic heart diseases (ICMs) at an 80% prevalence rate. Diagnostic tools, notably transthoracic echocardiography (TTE) and cardiac magnetic resonance imaging (CMR), demonstrate varying sensitivity but remain indispensable in specific clinical contexts related to LVT as non-invasive diagnostic modalities. A detailed comparison between ICM patients and those with non-ischemic cardiomyopathy (NICM) who have left ventricular thrombus reveals subtle distinctions with significant clinical implications. This analysis underscores the importance of these imaging techniques in distinguishing between the two conditions. Additionally, we explored the occurrence of LVT in specific non-ischemic cardiomyopathies, including Takotsubo syndrome, hypertrophic cardiomyopathy, eosinophilic myocarditis, Chagas disease, cardiac amyloidosis, and several other conditions. The article further delves into anticoagulation strategies, thoroughly examining their impact on LVT regression and patient outcomes. Pharmacological interventions, with a focus on direct oral anticoagulants, emerge as promising alternatives; however, there is insufficient information on their efficiency and safety, especially in NICM population. In conclusion, this review highlights the complex nature of LVT, incorporating a range of etiopathogenic factors, diagnostic complexities, and evolving therapeutic approaches. It emphasizes the pressing need for ongoing research in this field.

2.
Diagnostics (Basel) ; 13(21)2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37958264

RESUMO

At the beginning of 2020, coronavirus disease 2019 (COVID-19) emerged as a new pandemic, leading to a worldwide health crisis and overwhelming healthcare systems due to high numbers of hospital admissions, insufficient resources, and a lack of standardized therapeutic protocols. Multiple genetic variants of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have been detected since its first public declaration in 2020, some of them being considered variants of concern (VOCs) corresponding to several pandemic waves. Nevertheless, a growing number of COVID-19 patients are continuously discharged from hospitals, remaining symptomatic even months after their first episode of COVID-19 infection. Long COVID-19 or 'post-acute COVID-19 syndrome' emerged as the new pandemic, being characterized by a high variability of clinical manifestations ranging from cardiorespiratory and neurological symptoms such as chest pain, exertional dyspnoea or cognitive disturbance to psychological disturbances, e.g., depression, anxiety or sleep disturbance with a crucial impact on patients' quality of life. Moreover, Long COVID is viewed as a new cardiovascular risk factor capable of modifying the trajectory of current and future cardiovascular diseases, altering the patients' prognosis. Therefore, in this review we address the current definitions of Long COVID and its pathophysiology, with a focus on cardiovascular manifestations. Furthermore, we aim to review the mechanisms of acute and chronic cardiac injury and the variety of cardiovascular sequelae observed in recovered COVID-19 patients, in addition to the potential role of Long COVID clinics in the medical management of this new condition. We will further address the role of future research for a better understanding of the actual impact of Long COVID and future therapeutic directions.

3.
J Clin Med ; 12(11)2023 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-37297827

RESUMO

Left ventricular non-compaction (LVNC) with preserved ejection fraction (EF) is still a controverted entity. We aimed to characterize structural and functional changes in LVNC with heart failure with preserved EF (HFpEF). METHODS: We enrolled 21 patients with LVNC and HFpEF and 21 HFpEF controls. For all patients, we performed CMR, speckle tracking echocardiography (STE), and biomarker assessment for HFpEF (NT-proBNP), for myocardial fibrosis (Galectin-3), and for endothelial dysfunction [ADAMTS13, von Willebrand factor, and their ratio]. By CMR, we assessed native T1 and extracellular volume (ECV) for each LV level (basal, mid, and apical). By STE, we assessed longitudinal strain (LS), globally and at each LV level, base-to-apex gradient, LS layer by layer, from epicardium to endocardium, and transmural deformation gradient. RESULTS: In the LVNC group, mean NC/C ratio was 2.9 ± 0.4 and the percentage of NC myocardium mass was 24.4 ± 8.7%. LVNC patients, by comparison with controls, had higher apical native T1 (1061 ± 72 vs. 1008 ± 40 ms), diffusely increased ECV (27.2 ± 2.9 vs. 24.4 ± 2.5%), with higher values at the apical level (29.6 ± 3.8 vs. 25.2 ± 2.8%) (all p < 0.01); they had a lower LS only at the apical level (-21.4 ± 4.4 vs. -24.3 ± 3.2%), with decreased base-to-apex gradient (3.8 ± 4.7 vs. 6.9 ± 3.4%) and transmural deformation gradient (3.9 ± 0.8 vs. 4.8 ± 1.0%). LVNC patients had higher NT-proBNP [237 (156-489) vs. 156 (139-257) pg/mL] and Galectin-3 [7.3 (6.0-11.5) vs. 5.6 (4.8-8.3) ng/mL], and lower ADAMTS13 (767.3 ± 335.5 vs. 962.3 ± 253.7 ng/mL) and ADAMTS13/vWF ratio (all p < 0.05). CONCLUSION: LVNC patients with HFpEF have diffuse fibrosis, which is more extensive at the apical level, explaining the decrease in apical deformation and overexpression of Galectin-3. Lower transmural and base-to-apex deformation gradients underpin the sequence of myocardial maturation failure. Endothelial dysfunction, expressed by the lower ADAMTS13 and ADAMTS13/vWF ratio, may play an important role in the mechanism of HFpEF in patients with LVNC.

4.
Clin Case Rep ; 11(5): e7369, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37215966

RESUMO

Echocardiography is key in evaluating the cause of collapse in the post-cardiac surgery patient. Transesophageal echocardiography provides a greater capability for the diagnosis of pericardial effusion in patients who arrest after cardiac surgery.

6.
Int J Cardiovasc Imaging ; 39(3): 585-593, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36471103

RESUMO

PURPOSE: The aim of the present study was to evaluate the role of ejection fraction (EF), left ventricular (LV) global longitudinal strain (LVGLS) and global constructive work (GCW) as prognostic variables in patients with cardiac amyloidosis (CA). METHODS: CA patients were retrospectively identified between 2015 and 2021 at a tertiary care hospital. Comprehensive clinical, biochemical, and imaging evaluation including two-dimensional (2D) echocardiography with myocardial work (MW) analysis was performed. A clinical combined endpoint was defined as all-cause mortality and heart failure readmission. RESULTS: 70 patients were followed for 16 (7-37) months and 37 (52.9%) reached the combined endpoint. Patient with versus without clinical events had a significantly lower LVEF (40.71% vs. 48.01%, p = 0.039), LVGLS (-9.26 vs. -11.32, p = 0.034) and GCW (1034.47mmHg% vs. 1424.86mmHg%, p = 0.011). Multivariable analysis showed that LVEF ( odds ratio (OR): 0.904; 95% confidence interval (CI): 0.839-0.973, p = 0.007), LVGLS ( OR: 0.620; 95% CI: 0.415-0.926, p = 0.020) and GCW ( OR: 0.995; 95% CI: 0.990-0.999, p = 0.016) were significant predictors of outcome, but the model including GCW had the best discriminative ability to predict the combined endpoint (C-index = 0.888). A GCW less than 1443mmHg% was able to predict the clinical endpoint with a sensitivity of 94% and a specificity of 64% (Area under the curve (AUC): 0.771 (95% CI: 0.581-0.961; p = 0.005)). CONCLUSION: In CA patients, GCW may be of additional prognostic value to LVEF and GLS in predicting heart failure hospitalization and all-cause mortality.


Assuntos
Amiloidose , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Prognóstico , Estudos Retrospectivos , Volume Sistólico , Valor Preditivo dos Testes , Função Ventricular Esquerda
9.
PLoS One ; 17(5): e0267962, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35507565

RESUMO

AIMS: None of the conventional echocardiographic parameters alone predict increased NTproBNP level and symptoms, making diagnosis of heart failure with preserved ejection fraction (HFpEF) very difficult in some cases, in resting condition. We evaluated LA functions by 2D speckle tracking echocardiography (STE) on top of conventional parameters in HFpEF and preHF patients with diastolic dysfunction (DD), in order to establish the added value of the LA deformation parameters in the diagnosis of HFpEF. METHODS: We prospectively enrolled 125 patients, 88 with HFpEF (68±9 yrs), and 37 asymptomatic with similar risk factors with DD (preHF) (61±8 yrs). We evaluated them by NTproBNP, conventional DD parameters, and STE. Global longitudinal strain (GS) was added. LA reservoir (R), conduit (C), and pump function (CT) were assessed both by volumetric and STE. 2 reservoir strain (S) derived indices were also measured, stiffness (SI) and distensibility index (DI). RESULTS: LA R and CT functions were significantly reduced in HFpEF compared to preHF group (all p<0.001), whereas conduit was similarly in both groups. SI was increased, whereas DI was reduced in HFpEF group (p<0.001). By adding LA strain analysis, from all echocardiographic parameters, SR_CT<-1.66/s and DI<0.57 (AUC = 0.76, p<0.001) demonstrated the highest accuracy to identify HFpEF diagnosis. However, by multivariate logistic regression, the model that best identifies HFpEF included only SR_CT, GS and sPAP (R2 = 0.506, p<0.001). Moreover, SR_CT, DI, and sPAP registered significant correlation with NTproBNP level. CONCLUSIONS: By adding LA functional analysis, we might improve the HFpEF diagnosis accuracy, compared to present guidelines. LA pump function is the only one able to differentiates preHF from HFpEF patients at rest. A value of SR_CT < -1.66/s outperformed conventional parameters from the scoring system, reservoir strain, and LA overload indices in HFpEF diagnosis. We suggest that LA function by STE could be incorporated in the current protocol for HFpEF diagnosis at rest as a major functional criterion, in order to improve diagnostic algorithm, and also in the follow-up of patients with risk factors and DD, as a prognostic marker. Future studies are needed to validate our findings.


Assuntos
Função do Átrio Esquerdo , Insuficiência Cardíaca , Ecocardiografia/métodos , Átrios do Coração/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Fatores de Risco , Volume Sistólico , Função Ventricular Esquerda
10.
J Interv Card Electrophysiol ; 64(3): 751-757, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35239069

RESUMO

PURPOSE: Radiofrequency (RF) catheter ablation is widely accepted as a first-line therapy for cavotricuspid isthmus (CTI)-dependent atrial flutter (AFL). The novel DiamondTemp (DT) catheter with temperature feedback during RF ablation has been released recently on the market. The purpose of this study was to evaluate the impact of DiamondTemp (DT) technology on ablation efficiency during AFL. METHODS: In this single-center study, 30 consecutive patients with typical AFL indicated to ablation of CTI were included. The first 15 patients underwent CTI ablation using 8-mm tip catheter, and the following 15 patients underwent temperature-controlled RF ablation using DT catheter. The endpoints were number and mean total duration of RF applications, mean temperature reached in the setting of CTI, procedural times, and fluoroscopy times. RESULTS: There were no significant differences between the two groups concerning baseline characteristics. Mean duration of the each application (71.5 s ± 30.6 vs 12.4 s ± 13.2, p value < 0.001), mean total duration of RF applications (517,73 s ± 377,96 vs 112,8 s ± 43,58; p value < 0.001), procedural times (51.6 min ± 24.2 vs 38.6 ± 8.2; p = 0.03), and fluoroscopy times (16.2 min ± 10.2 vs 8 min ± 4.24; p = 0.005) were longer in the 8-mm ablation catheter group. Mean temperature measurements (51.9 °C ± 3.59 vs 56.7 °C ± 3.34, p value < 0.003) were as well lower in the 8-mm ablation catheter group. CONCLUSIONS: Catheter ablation of CTI-dependent AFL by means of DT resulted in a significant reduction of total and single application RF delivery time, procedure, and fluoroscopy times.


Assuntos
Flutter Atrial , Ablação por Cateter , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Catéteres , Diamante , Humanos , Temperatura , Resultado do Tratamento , Valva Tricúspide/cirurgia
11.
Artigo em Inglês | MEDLINE | ID: mdl-34919165

RESUMO

Cryoballoon ablation (CBA) is a safe and efficient therapeutic option for atrial fibrillation (AF). However, AF recurrence occurs in 25% of the patients, leading to repeated ablations and complications. Previous reports have shown that left atrium (LA) assessed by M-Mode and two-dimensional echocardiography (2DE) predicts AF recurrence. Nevertheless, these methods imply geometrical assumptions of the LA remodeling, which is a three-dimensional process. We hypothesized that LA remodeling by three-dimensional echocardiography (3DE) has an additional value for AF recurrence prediction post-CBA. 172 consecutive patients (62.2 ± 12.2 years, 61% male) were prospectively recruited. Echocardiography was performed before CBA. Blanking period was defined as the first three months post-ablation. The primary endpoint was AF recurrence after the blanking period. 50 (29%) patients had AF recurrence. 3DE LA maximum volume index (LAVI) had the highest incremental predictive value for AF recurrence (HR 5.50, 95% CI 1.34 -22.45, p < 0.001). In patients with non-dilated LA diameter index and LAVI by 2DE, LAVI by 3DE was able to discriminate AF recurrence with a sensitivity of 90% and a specificity of 66%, for an optimal cut-off value of 30.4 ml/m2. LA remodeling by 3DE predicted AF recurrence, even in patients with non-dilated LA by M-Mode and 2DE, suggesting that 3DE might reflect better and earlier the asymmetric and variable nature of LA remodeling and it should be considered for systematic use to evaluate AF recurrence risk post-CBA.

12.
PLoS One ; 16(11): e0259999, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34797844

RESUMO

OBJECTIVE: Atrial fibrillation (AF) recurrence occurs in approximately 25% of the patients undergoing cryoballoon ablation (CBA), leading to repeated ablations and complications. Left atrial (LA) dilation has been proposed as a predictor of AF recurrence. However, LA strain is a surrogate marker of LA mechanical dysfunction, which might appear before the enlargement of the LA. The purpose of this study was to evaluate the additional predictive value of LA function assessed using strain echocardiography for AF recurrence after CBA. METHODS: 172 consecutive patients (62.2 ± 12.2 years, 61% male) were prospectively analyzed. Echocardiography was performed before CBA. Blanking period was defined as the first three months post-ablation. The primary endpoint was AF recurrence after the blanking period. RESULTS: 50 (29%) patients had AF recurrence. In the overall study population, peak atrial longitudinal strain (PALS) ≤ 17% had the highest incremental predictive value for AF recurrence (HR = 9.45, 95%CI: 3.17-28.13, p < 0.001). In patients with non-dilated LA, PALS≤17% remained an independent predictor of AF recurrence (HR = 5.39, 95%CI: 1.66-17.52, p = 0.005). CONCLUSIONS: This study showed that LA function assessed by PALS provided an additional predictive value for AF recurrence after CBA, over LA enlargement. In patients with non-dilated LA, PALS also predicted AF recurrence. These findings emphasize the added value of LA strain, suggesting that it should be implemented in the systematic evaluation of AF patients before CBA.


Assuntos
Fibrilação Atrial/prevenção & controle , Função do Átrio Esquerdo/fisiologia , Criocirurgia/efeitos adversos , Idoso , Criocirurgia/métodos , Testes Diagnósticos de Rotina/métodos , Ecocardiografia/métodos , Feminino , Átrios do Coração/fisiopatologia , Humanos , Hipertrofia/fisiopatologia , Masculino , Pessoa de Meia-Idade
13.
Cardiol J ; 28(6): 807-815, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34581431

RESUMO

BACKGROUND: Coronavirus disease 2019 (COVID-19) emerged as a worldwide health crisis, overwhelming healthcare systems. Elevated cardiac troponin T (cTn T) at admission was associated with increased in-hospital mortality. However, data addressing the role of cTn T in major adverse cardiovascular events (MACE) in COVID-19 are scarce. Therefore, we assessed the role of baseline cTn T and cTn T kinetics for MACE and in-hospital mortality prediction in COVID-19. METHODS: Three hundred and ten patients were included prospectively. One hundred and eight patients were excluded due to incomplete records. Patients were divided into three groups according to cTn T kinetics: ascending, descending, and constant. The cTn T slope was defined as the ratio of the cTn T change over time. The primary and secondary endpoints were MACE and in-hospital mortality. RESULTS: Two hundred and two patients were included in the analysis (mean age 64.4 ± 16.7 years, 119 [58.9%] males). Mean duration of hospitalization was 14.0 ± 12.3 days. Sixty (29.7%) patients had MACE, and 40 (19.8%) patients died. Baseline cTn T predicted both endpoints (p = 0.047, hazard ratio [HR] 1.805, 95% confidence interval [CI] 1.009-3.231; p = 0.009, HR 2.322, 95% CI 1.234-4.369). Increased cTn T slope predicted mortality (p = 0.041, HR 1.006, 95% CI 1.000-1.011). Constant cTn T was associated with lower MACE and mortality (p = 0.000, HR 3.080, 95% CI 1.914-4.954, p = 0.000, HR 2.851, 95% CI 1.828-4.447). CONCLUSIONS: The present study emphasizes the additional role of cTn T testing in COVID-19 patients for risk stratification and improved diagnostic pathway and management.


Assuntos
COVID-19 , Troponina T , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , COVID-19/diagnóstico , Feminino , Humanos , Cinética , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Troponina T/sangue
14.
Front Cardiovasc Med ; 8: 684528, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34307498

RESUMO

Background: The association of known cardiovascular risk factors with poor prognosis of coronavirus disease 2019 (COVID-19) has been recently emphasized. Coronary artery calcium (CAC) score is considered a risk modifier in the primary prevention of cardiovascular disease. We hypothesized that the absence of CAC might have an additional predictive value for an improved cardiovascular outcome of hospitalized COVID-19 patients. Materials and methods: We prospectively included 310 consecutive hospitalized patients with COVID-19. Thirty patients with history of coronary artery disease were excluded. Chest computed tomography (CT) was performed in all patients. Demographics, medical history, clinical characteristics, laboratory findings, imaging data, in-hospital treatment, and outcomes were retrospectively analyzed. A composite endpoint of major adverse cardiovascular events (MACE) was defined. Results: Two hundred eighty patients (63.2 ± 16.7 years old, 57.5% male) were included in the analysis. 46.7% patients had a CAC score of 0. MACE rate was 21.8% (61 patients). The absence of CAC was inversely associated with MACE (OR 0.209, 95% CI 0.052-0.833, p = 0.027), with a negative predictive value of 84.5%. Conclusion: The absence of CAC had a high negative predictive value for MACE in patients hospitalized with COVID-19, even in the presence of cardiac risk factors. A semi-qualitative assessment of CAC is a simple, reproducible, and non-invasive measure that may be useful to identify COVID-19 patients at a low risk for developing cardiovascular complications.

15.
Diagnostics (Basel) ; 11(4)2021 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-33919794

RESUMO

Three-dimensional echocardiography (3DE) is advised for right ventricular (RV) assessment. Data regarding the optimal acquisition settings and optimization are still scarce. We aimed to evaluate the feasibility, reproducibility and validation of 3DE for RV volume and function assessment, using cardiac magnetic resonance (CMR) as gold standard. Thirty healthy volunteers and 36 consecutive patients were prospectively included. CMR was performed in the latter. Standard apical four-chamber view (A4CV), focused A4CV and modified A4CV were used for 3DE RV acquisition. Feasibility (and the effect of changes in settings) was evaluated. Intra and interobserver analyses were performed by three observers (expert vs. novice). RV parameters by echocardiography were compared to CMR. Feasibility of acquisition was 16.7% for A4CV, 80.0% for focused A4CV and 16.7% for modified A4CV. Changes in settings had no significant influence on feasibility and further analysis. Intraobserver variability was good in both expert and novice, interobserver variability was good between experienced observers. Compared to CMR, 3DE volumes were significantly lower with fair to moderate correlation (EDV: 91.1 ± 24.4 mL vs. 144.3 ± 43.0 mL (p < 0.001), r = 0.653 and ESV: 48.1 ± 16.4 mL vs. 60.4 ± 21.2 mL (p < 0.001), r = 0.530, by multi-beat 3DE and CMR respectively). These findings suggest that standardization is needed in order to implement this technique in clinical practice, thus further studies are required.

16.
Diagnostics (Basel) ; 12(1)2021 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-35054224

RESUMO

Long coronavirus disease 2019 (COVID-19) was described in patients recovering from COVID-19, with dyspnea being a frequent symptom. Data regarding the potential mechanisms of long COVID remain scarce. We investigated the presence of subclinical cardiac dysfunction, assessed by transthoracic echocardiography (TTE), in recovered COVID-19 patients with or without dyspnea, after exclusion of previous cardiopulmonary diseases. A total of 310 consecutive COVID-19 patients were prospectively included. Of those, 66 patients (mean age 51.3 ± 11.1 years, almost 60% males) without known cardiopulmonary diseases underwent one-year follow-up consisting of clinical evaluation, spirometry, chest computed tomography, and TTE. From there, 23 (34.8%) patients reported dyspnea. Left ventricle (LV) ejection fraction was not significantly different between patients with or without dyspnea (55.7 ± 4.6 versus (vs.) 57.6 ± 4.5, p = 0.131). Patients with dyspnea presented lower LV global longitudinal strain, global constructive work (GCW), and global work index (GWI) compared to asymptomatic patients (-19.9 ± 2.1 vs. -21.3 ± 2.3 p = 0.039; 2183.7 ± 487.9 vs. 2483.1 ± 422.4, p = 0.024; 1960.0 ± 396.2 vs. 2221.1 ± 407.9, p = 0.030). GCW and GWI were inversely and independently associated with dyspnea (p = 0.035, OR 0.998, 95% CI 0.997-1.000; p = 0.040, OR 0.998, 95% CI 0.997-1.000). Persistent dyspnea one-year after COVID-19 was present in more than a third of the recovered patients. GCW and GWI were the only echocardiographic parameters independently associated with symptoms, suggesting a decrease in myocardial performance and subclinical cardiac dysfunction.

17.
Diagnostics (Basel) ; 10(12)2020 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-33287239

RESUMO

Left atrium (LA) volume is a biomarker of cardiovascular outcomes. Three-dimensional echocardiography (3DE) provides an accurate LA evaluation, but data regarding the optimal 3DE method is scarce. We assessed the feasibility and reproducibility of LA measurements using different 3DE methods. One hundred and ninety-four patients were prospectively analyzed. Conventional 3DE and two semi-automatic 3DE algorithms (Tomtec™ and Dynamic Heart Model (DHM)) were used in 110 patients. Intra- and interobserver reproducibility and intervendor comparison were performed in additional patients' subsets. Forty patients underwent cardiac magnetic resonance (CMR). Feasibility was 100% for Tomtec, 98.2% for DHM, and 72.8% for conventional 3DE. Tomtec volumes were higher than 3DE and DHM (p < 0.001). Reproducibility was better for DHM (intraobserver LA maximum volume (LAmax) ICC 0.99 (95% CI 1.0-0.99), LA minimum volume (LAmin) 0.98 (95% CI 0.95-0.99), LApreA 0.96 (95% CI 0.91-0.98); interobserver LAmax ICC 0.98 (95% CI 0.96-0.99), LAmin 0.99 (95% CI 0.99-1.00), and LApreA 0.97 (95% CI 0.94-0.99)). Intervendor comparison showed differences between left ventricle (LV) software adapted for LA (p < 0.001). Tomtec underestimated the least LA volumes compared to CMR. These findings emphasize that dedicated software should be used for LA assessment, for consistent clinical longitudinal follow-up and research.

19.
Eur Heart J Cardiovasc Imaging ; 21(7): 709-714, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32391912

RESUMO

Recent EACVI recommendations described the importance of limiting cardiovascular imaging during the COVID-19 pandemic in order to reduce virus transmission, protect healthcare professionals from contamination, and reduce consumption of personal protective equipment. However, an elevated troponin remains a frequent request for cardiac imaging in COVID-19 patients, partly because it signifies cardiac injury due to a variety of causes and partly because it is known to convey a worse prognosis. The present paper aims to provide guidance to clinicians regarding the appropriateness of cardiac imaging in the context of troponin elevation and myocardial injury, how best to decipher the mechanism of myocardial injury, and how to guide patient management.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Infecções por Coronavirus/epidemiologia , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/epidemiologia , Pandemias/estatística & dados numéricos , Pneumonia Viral/epidemiologia , Troponina I/sangue , Biomarcadores , COVID-19 , Técnicas de Imagem Cardíaca/estatística & dados numéricos , Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/epidemiologia , Comorbidade , Infecções por Coronavirus/prevenção & controle , Gerenciamento Clínico , Ecocardiografia Doppler/métodos , Ecocardiografia Doppler/estatística & dados numéricos , Eletrocardiografia/métodos , Eletrocardiografia/estatística & dados numéricos , Feminino , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Guias de Prática Clínica como Assunto , Prognóstico , Medição de Risco , Papel (figurativo)
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...